当前位置:主页 > 产品中心 > LPG PUMPS >
Colioris Mass Flow Meter添加时间:6/30/2020 9:39:56 AM
 

Colioris  Mass Flow Meter 
  

I . Main technical parameters
(I) Measurement scope :2kg/h~500t/h
(II) Accuracy :±0.2%~±0.15%
(III) Work pressure :(0~32) MPa (in case of other high pressure, it must be of special order)
(IV) Medium temperature :-50℃~ +350℃,
measurement accuracy :±1℃
(V) Environment temperature : -20℃ ~ +70℃
(VI) Measurement medium: liquid, gas, solid, or two phases and three phases mixed fluid
(VII) Output signal:
(1) 4-20mA current signal of flow, with load resistance ≤500Ω
(2) 0-10KHz frequency signal of flow.
(3) RS485 Communication protocol
(4) Hart protocol
(VIII) Power supply voltage: 24VDC
(IX) Measurement of measuring pipe: 316L stainless steel
(X) Response time: 0.1s~5s, adjustable
(XI) Explosion-proof grade: Ex(ib)II BT2-T5